Whole-window U-value
0.045
W/m²K equiv. R-22
Calculated · LBNL
SHGC range
0.20–0.50
by glass package
Project-specific
Air infiltration
≤0.05
cfm/ft² target
In testing
Condensation (CRF)
80+
triple-glazed target
Calculated

Fiberglass frame

Pultruded glass fiber moves with the glazing and barely conducts heat, so the frame edge stays warm and the seals are not stressed by temperature swings.

Vacuum & triple glazing

A hybrid GR85 pocket stacks an outer lite, an argon cavity, and a vacuum unit into 42 mm, approaching wall-level insulation without wall-level thickness.

Certification underway

NFRC and CSA testing is in progress. Until each label is issued, modeled values are shown as Calculated so the record stays honest.